Is a 30 x 24 clear opening big enough for egress?
A clear opening 30 in wide by 24 in high is 5.00 sq ft. That is under the 5.7 sq ft minimum and meets only the 5 sq ft minimum for a grade-floor opening. These are clear opening sizes, not the size on the window label: measure yours and enter it below.
- Net clear opening area (30 in × 24 in)
- 5.00 sq ft
- Against the 5.7 sq ft minimum
- Fails, 100.8 sq in short
- Against the 5 sq ft minimum for a grade-floor opening
- Passes
- Clear height needed at 30 in wide for 5.7 sq ft
- 27 3/8 in
- Clear width needed at 24 in high for 5.7 sq ft
- 34 1/4 in
- 30 x 24 here is the clear opening, not the size a window is sold by
- measure yours
2021 IRC Section R310. Width first, then height, both measured as the free opening with the window opened the normal way. This tool applies the 5 sq ft minimum only where the bottom of the opening is at or above the ground outside and no more than 44 in above it. An opening below the ground is held to 5.7 sq ft and must also have a window well. The bottom of the opening must be no more than 44 in above the floor.
Rule: 2021 IRC R310 · Tested against 29 worked examples, 9 printed in a published source · How this is worked out →